Reinforced Cement Conerete          Non Pressure Pipe
 Tank
 
 
Quality
 
 
Pipe QAP
Sr. No.
Test Parameters
Frequency of Check
Acceptance Criteria
Referance Document
Records
1
Documents
Review
As per Tender Document
IS:458:2003
IS3597:1998
1) Caliberation Certificate of Pressure Gauge
2) Mix Design of Concrete
3) M.T.C. of Steel & Cement
4) Cube Testing
5) Test Certificate of Raw materials
6) Pipe Register
2
Dimentional Check
No. of pipes in lot
Sampling Required
Up to 50
8
51 to 100
13
101 to 300
20
301 to 500
32
As per Is:458:2003
Table no 23
IS:458:2003
IS3597:1998
Testing Format
3
Hydro Test
2% of the pipe offered
As per IS:458:2003
Clause no.10.3
IS:458:2003
IS3597:1998
Testing Format
4
Three Edge Bearing Test
(Including Ultimate Load)
No. of pipes in lot
Test Required
Up to 50
4%
51 to 100
3%
101 to 300
3%
301 to 500
3%
500 to above
2%
As per Is:458:2003
IS:458:2003
IS3597:1998
Testing Format
5
Visual Inspection 100%of the pipesoffered
As per Is:458:2003
IS:458:2003
IS3597:1998
Testing Format
6
Reinforcement checking
No. of pipes in lot
Test Required
Up to 50
2%
51 to 100
2%
101 to 300
1%
301 to 500
1%
500 to above
1%
As per Is:458:2003
IS:458:2003
IS3597:1998
Testing Format
7
Permablity Specimen Selected at random
with a surface area dry length
of the pipe to be laid
As per Is:458:2003
IS:458:2003
IS3597:1998
Testing Format
8
Straightness Text Specimen Selected at random
As per Is:458:2003
IS:458:2003
IS3597:1998
Testing Format